Blue-sky IPN Pro User Manual

Browse online or download User Manual for Sensors Blue-sky IPN Pro. Blue Sky IPN Pro User Manual

  • Download
  • Add to my manuals
  • Print
  • Page
    / 64
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
IPN-ProRemote
IPN
network compatible charge controller and battery system monitor
INSTALLATION AND OPERATION MANUAL
THIS MANUAL INCLUDES IMPORTANT SAFETY INSTRUCTIONS FOR MODELS - IPNPRO, IPNPRO-S
SAVE THESE INSTRUCTIONS
ESTE MANUAL INCLUYE INSTRUCCIONES DE SEGURIDAD IMPORTANTES PARA LOS MODELOS - IPNPRO, IPNPRO-S
CONSERVE ESTAS INSTRUCCIONES
CE MANUEL CONTIENT D’INSTRUCTIONS IMPORTANTES POUR LES MODELES - IPNPRO, IPNPRO-S
PRIERE DE SAUVEGARDER CES INSTRUCTIONS
DIESES HANDBUCH ENTHÄLT WICHTIGE HINWEISE FÜR DIE MODELLE - IPNPRO, IPNPRO-S
BITTE BEHALTEN SIE DIESE HINWEISE
© Blue Sky Energy, Inc. 2008 430-0019 E
This device complies with part 15 of the FCC
rules. Operation is subject to the following two
conditions: 1) This device may not cause harmful
interference, and 2) This device must accept any
interference received, including interference that
may cause undesired operations.
CONFORMS TO
EN 61326-1:2006
EN 60335-1:2002 + A11:2004 + A1:2004
EN 60335-2-29:2004
Page view 0
1 2 3 4 5 6 ... 63 64

Summary of Contents

Page 1 - IPN-ProRemote

IPN-ProRemote IPN™ network compatible charge controller and battery system monitor INSTALLATION AND OPERATION MANUAL

Page 2

Blue Sky Energy – IPN-ProRemote 9 USING THE MENUS AND KEYS Moving through the menus, functions and changing settings is consistent throughout all f

Page 3 - PRODUCT DESCRIPTION

Installation and Operation Manual 10 IPN-ProRemote SETUP ¾ The IPN-ProRemote has various setup parameters all of which are preconfigured at the fac

Page 4 - OPERATION

Blue Sky Energy – IPN-ProRemote 11 Float Transition Current “Time in Acceptance” is an accepted method to determine when the battery is fully charg

Page 5

Installation and Operation Manual 12 CURRENT SHUNT ¾ CAUTION: A 500A/50mV current shunt must be used with the IPN-ProRemote. The shunt is used to m

Page 6

Blue Sky Energy – IPN-ProRemote 13 ¾ When Backlight is on, the IPN-ProRemote can draw up to 100mA from the charge controller. For proper operation

Page 7 -  From Top menu

Installation and Operation Manual 14 SYMPTOM PROBABLE CAUSE ITEMS TO EXAMINE OR CORRECT No data shows in the View Charge Unit Status screen Charg

Page 8 -  From Advanced Display menu

Blue Sky Energy – IPN-ProRemote 15 SPECIFICATIONS SPECIFICATIONS IPN-ProRemote Current Shunt 50 mV / 500 amp Battery Ammeter Range ±773.3A FS •

Page 9 -  From Setup menu

Installation and Operation Manual 16 IPN-ProRemote Controlador de carga compatible con red IPN™ y monitor de sistema de baterías MANUAL DE I

Page 10 - INSTALLATION

Blue Sky Energy – IPN-ProRemote 17 TABLA DE CONTENIDOS INSTRUCCIONES DE SEGURIDAD IMPORTANTES...

Page 11

Installation and Operation Manual 18 INSTRUCCIONES IMPORTANTES DE SEGURIDAD Este manual contiene instrucciones importantes para los modelos IPNPRO

Page 12

Blue Sky Energy – IPN-ProRemote 1 TABLE OF CONTENTS IMPORTANT SAFETY INSTRUCTIONS...

Page 13 - the purpose of testing

Blue Sky Energy – IPN-ProRemote 19 PANEL DEL VISOR FIGURA 1 OPERACIÓN Todas las operaciones del IPN-ProRemote y las pantallas son controladas po

Page 14

Installation and Operation Manual 20 VISOR DE LCD Y RETROILUMINACIÓN El visor de cristal líquido (LCD) puede ser retroiluminado para mejorar la leg

Page 15 - Remaining Battery

Blue Sky Energy – IPN-ProRemote 21 Precisión La capacidad remanente de batería tenderá a ser mejor si: • El controlador de carga provee al menos

Page 16 - TWO YEAR LIMITED WARRANTY

Installation and Operation Manual 22 MENÚ DE VISOR AVANZADO  Del menú superior  A lo

Page 17

Blue Sky Energy – IPN-ProRemote 23 Menú de configuración  Del menú de visor avanzado Advanced Display

Page 18

Installation and Operation Manual 24 MENÚ DE PARÁMETROS DE CARGA DE BATERÍA  Del menú de configuración

Page 19 - DESCRIPCIÓN DEL PRODUCTO

Blue Sky Energy – IPN-ProRemote 25 USO DE LOS MENÚS Y LAS TECLAS La forma de moverse a través de los menús, funciones y cambiar ajustes es constant

Page 20 - OPERACIÓN

Installation and Operation Manual 26 Configuración del IPN-ProRemote ¾ El IPN-ProRemote tiene varios parámetros de configuración, todos ellos son

Page 21

Blue Sky Energy – IPN-ProRemote 27 Corriente flotante de transición El tiempo en aceptación “Time in Acceptance” es un método aceptado para determi

Page 22 - 

Installation and Operation Manual 28 DERIVACIÓN DE CORRIENTE ¾ PRECAUCIÓN: Debe usarse un derivador de corriente de 500A/50mV con el IPN-ProRemote.

Page 23 - 

Installation and Operation Manual 2 IMPORTANT SAFETY INSTRUCTIONS This manual contains important instructions for Models IPNPRO and IPNPRO-S SAVE T

Page 24 - 

Blue Sky Energy – IPN-ProRemote 29 ¾ Cuando la retroiluminación está encendida, el IPN-ProRemote puede consumir hasta 100mA del controlador de carga

Page 25 -  Del menú de configuración

Installation and Operation Manual 30 No aparecen datos en la pantalla de estado de unidad de carga “View Charge Unit Status” El controlador de carga

Page 26 - INSTALACIÓN

Blue Sky Energy – IPN-ProRemote 31 ESPECIFICACIONES ESPECIFICACIONES IPN-ProRemote Derivador de corriente 50 mV / 500 A Amperímetro de batería R

Page 27

Installation and Operation Manual 32 IPN-ProRemote Contrôleur de système de batterie et de régulateur de charge compatible IPN™ MANUEL D&ap

Page 28

Blue Sky Energy – IPN-ProRemote 33 TABLE DES MATIÈRES INSTRUCTIONS DE SÉCURITÉ IMPORTANTES...

Page 29

Installation and Operation Manual 34 INSTRUCTIONS DE SÉCURITÉ IMPORTANTES Ce manuel contient des instructions importantes pour les modèles IPNPRO e

Page 30

Blue Sky Energy – IPN-ProRemote 35 FAÇADE DE L'AFFICHEUR FIGURE 1 FONCTIONNEMENT Toutes les opérations et tous les affichages de l'IPN

Page 31

Installation and Operation Manual 36 AFFICHEUR LCD ET RÉTROÉCLAIRAGE L'afficheur à cristaux liquides (LCD) peut être rétroéclairé pour amélior

Page 32 - ESPECIFICACIONES

Blue Sky Energy – IPN-ProRemote 37 Précision La capacité restante de la batterie tend à être plus exacte si : • Le régulateur de charge fournit a

Page 33

Installation and Operation Manual 38 Menu ADVANCED DISPLAY (affichage avancé)  Depuis le menu Top

Page 34

Blue Sky Energy – IPN-ProRemote 3 DISPLAY PANEL FIGURE 1 OPERATION All IPN-ProRemote operations and displays are controlled with the three funct

Page 35 - DESCRIPTION DU PRODUIT

Blue Sky Energy – IPN-ProRemote 39 Menu SETUP (configuration)  Depuis le menu Adanced Display

Page 36 - FONCTIONNEMENT

Installation and Operation Manual 40 Menu BATTERY CHARGE PARAMETERS (paramètres de charge de la batterie)  Depuis le menu Setup

Page 37

Blue Sky Energy – IPN-ProRemote 41 UTILISER LES MENUS ET LES TOUCHES La navigation à travers les menus, les fonctions et les réglages est uniforme

Page 38

Installation and Operation Manual 42 CONFIGURATION DE L'IPN-ProRemote ¾ L'IPN-ProRemote présente divers paramètres de configuration qui s

Page 39 -  Depuis le menu Top

Blue Sky Energy – IPN-ProRemote 43 Intensité de transition d'entretien La « durée en charge à capacité » est une méthode acceptée pour détermi

Page 40

Installation and Operation Manual 44 SHUNT DE COURANT ¾ ATTENTION : Un shunt de courant de 500 A/50 mV doit être utilisé avec l'IPN-ProRemote.

Page 41 -  Depuis le menu Setup

Blue Sky Energy – IPN-ProRemote 45 ¾ Lorsque le rétroéclairage est allumé, l'IPN-ProRemote tire jusqu'à 100 mA du régulateur de charge. P

Page 42

Installation and Operation Manual 46 SYMPTÔME CAUSE PROBABLE POINTS À EXAMINER OU À CORRIGER Aucune donnée affichée dans l'écran View Charge

Page 43

Blue Sky Energy – IPN-ProRemote 47 CARACTÉRISTIQUES TECHNIQUES CARACTÉRISTIQUES TECHNIQUES IPN-ProRemote Shunt de courant 50 mV / 500 A Ampèremèt

Page 44

Installation and Operation Manual 48 IPN-ProRemote IPN™ Netzwerkkompatibler Laderegler und Batteriesystem-Monitor INSTALLATION UND BEDIENERH

Page 45

Installation and Operation Manual 4 LCD DISPLAY AND BACKLIGHT The Liquid Crystal Display (LCD) may be backlit for improved readability. Switching b

Page 46

Blue Sky Energy – IPN-ProRemote 49 INHALTSVERZEICHNIS WICHTIGE SICHERHEITSANWEISUNGEN...

Page 47

Installation and Operation Manual 50 WICHTIGE SICHERHEITSANWEISUNGEN Dieses Handbuch enthält wichtige Answeisungen für die Modelle IPNPRO und IPNPR

Page 48 - GARANTIE LIMITÉE DEUX ANS

Blue Sky Energy – IPN-ProRemote 51 Informationen im Menü "Advanced Display“ (fortgeschrittene Anzeigen) sehen, während bei der Installation mög

Page 49

Installation and Operation Manual 52 LCD-ANZEIGE UND HINTERGRUNDBELEUCHTUNG Der Hintergrund der Flüssigkeitskristallanzeige (LCD) kann zur besseren

Page 50

Blue Sky Energy – IPN-ProRemote 53 Genauigkeit Der Wert für „Remaining Battery Capacity“ (verbleibende Batterieladekapazität) neigt zu besserer Gen

Page 51 - BETRIEB

Installation and Operation Manual 54 Menü “ADVANCED DISPLAY“ (fortgeschrittene Anzeigen)  Vom Hauptmenü

Page 52

Blue Sky Energy – IPN-ProRemote 55 Menü „SETUP“ (Konfiguration)  Vom Menü “Advanced Display” (fortgeschrittene Anzeigen)

Page 53

Installation and Operation Manual 56 Menü “BATTERY CHARGE PARAMETERS” (Batterieladeparameter)  Vom Menü “Setup” (Konfiguration)

Page 54

Blue Sky Energy – IPN-ProRemote 57 VERWENDUNG DER MENÜS UND TASTEN Die Navigation durch die Menüs und Funktionen sowie die Änderung von Einstellung

Page 55 -  Vom Hauptmenü

Installation and Operation Manual 58 Konfiguration des IPN-ProRemote ¾ Der IPN-ProRemote verfügt über verschiedene Konfigurationsparameter, die all

Page 56

Blue Sky Energy – IPN-ProRemote 5 Accuracy Remaining Battery Capacity will tend to be better if; • The charge controller delivers at least 3 amp

Page 57

Blue Sky Energy – IPN-ProRemote 59 Pufferladungsübergangs-Stromstärke “Time in Acceptance” (Zeit in Grundladung) ist eine akzeptierte Methode, um z

Page 58

Installation and Operation Manual 60 Stromableitungs-Signalverkabelung Die Stromableitung selbst ist ein unpolarisiertes Gerät. Sobald diese in Rei

Page 59

Blue Sky Energy – IPN-ProRemote 61 ¾ Wenn die Hintergrundbeleuchtung eingeschaltet ist, dann kann der IPN-ProRemote bis zu 100 mA vom Laderegler zi

Page 60

Installation and Operation Manual 62 “Days since last equalize or full charge” (Zeit seit letzter Abgleich- bzw. vollständiger Ladung) zeigt 1 Tag z

Page 61

Blue Sky Energy – IPN-ProRemote 63 TECHNISCHE ANGABEN TECHNISCHE ANGABEN IPN-ProRemote Stromableitung 50 mV / 500 A Batterie-Stromstärkemesser Be

Page 62

Installation and Operation Manual 6 ADVANCED DISPLAY Menu  From Top menu  To Setup m

Page 63

Blue Sky Energy – IPN-ProRemote 7 SETUP Menu  From Advanced Display menu

Page 64 - TECHNISCHE ANGABEN

Installation and Operation Manual 8 BATTERY CHARGE PARAMETERS Menu  From Setup menu FIGURE 5 SE

Comments to this Manuals